Specifications
Model | RDX-04 | RDX-06 | RDX-09 | RDX-12 | RDX-18 |
Air flow* (m3/min) | 0,4 | 0,6 | 0,9 | 1,2 | 1,8 |
Max. working pressure (bar) | 16 | 16 | 16 | 16 | 16 |
Screw connection | 1/2" | 1/2" | 3/4" | 3/4" | 3/4" |
Rated voltage (Phase/V/Hz) | 1/230/50 | 1/230/50 | 1/230/50 | 1/230/50 | 1/230/50 |
Drive power (kW) | 0,1 | 0,2 | 0,2 | 0,3 | 0,3 |
Length L (mm) | 540 | 540 | 540 | 540 | 540 |
Width W (mm) | 370 | 370 | 370 | 370 | 370 |
Height H (mm) | 500 | 500 | 500 | 500 | 500 |
Weight (kg) | 34 | 35 | 36 | 36 | 38 |
* Measured according to ISO 1217
RDX-series refrigerated dryers with a capacity of 0.4-36.0 m3/min are equipped with an efficient cast-aluminium heat exchanger and an inbuilt coalescence separator. The low degree of pressure loss due to the inbuilt separator and the reliable outer insulation of the heat exchanger facilitate a high level of energy efficiency for the system. The coalescence separator is insensitive to pressure fluctuations in the case of varying load and reliably removes up to 98% of condensed moisture.
Features
Adjusting dryer's capacity for different operating conditions
For complete drying of compressed air, it is necessary to use refrigerated dryers. RDX series dehumidifiers are a robust design with low pressure loss and high efficiency.
The capacity applies to a working pressure of 7 bar, a compressed air temperature at the dryer's inlet of 35°C and an ambient temperature of 25°C, according to DIN ISO 7183. In order to calculate the dryer's capacity for real operating conditions at the dryer's inlet, please use the following correction coefficients:
Capacity(air compressor) x F1 x F2 x F3 = Capacity(dryer).
Example:
For an air compressor capacity of 1.6 m3/min, a working pressure of 4 bar, a compressed air temperature at the dryer's inlet of 45°C and an ambient temperature of 35°C, the required capacity of the refrigerated dryer is calculated as follows:
Capacity (dryer) = 1.6 x 1.25 x 1.39 x 1.14 = 3.169 m3/min.